Section 2Installation References
2-2
Clearance Requirements
Check the Reach-In unit for proper clearance
from walls, boxes, or other objects. The
clearances given below are minimums.
6” (15 cm) at the back and each side
12” (30 cm) above the condensing unit
CAUTION
If the minimum clearances are not
maintained, cooling capacity will be reduced.
This may lead to product loss and premature
component failure.
WARNING
Reach-In units are susceptible to tipping.
Never move a Reach-In unit with the door(s)
open. Always use two people to move a
Reach-In unit.
Air Temperature Entering Condenser
Minimum Maximum
50°F (10°C) 110°F (43.3°C)